The Suggested Electrode Number in Electrocardiographic Imaging for Identifying Atrial Fibrillation Drivers

Yadan Zhang1, Wu Jian2, Xiang Min1, Cui Yangyang1
1Hangzhou Institute of National Extremely-weak Magnetic Field Infrastructure, 2Shenzhen International Graduate School, Tsinghua University


Abstract

Electrocardiographic imaging (ECGI) is expected to map the epicardial potential non-invasively and globally and identify the atrial fibrillation (AF) drivers. There is currently no uniform standard in ECGI for the selection of the ideal electrode number on the body surface. From the original 128 surface electrodes, we selected out 112, 96, 80, 72, 64, 48, 32, 24, and 12 electrodes using an enhanced spectral clustering approach.
6 paroxysmal and 4 persistent AF patients were enrolled in the study. By examining the relevance and correctness of atrial epicardial electrical activity reconstructed by the ECGI under varying numbers of body surface electrodes, the suggested minimum numbers of electrodes for paroxysmal and persistent AF are identified, respectively. For persistent AF, it is recommended that the minimum number of electrodes be greater than 48 (such as 64 and above); for paroxysmal AF, when the minimum number of electrodes is 48, the reconstructed potential map can maintain a high similarity with the potential maps obtained by ECGI with higher number of electrodes.